Free DNDNS-200 Exam Questions Free Download – [March-2018 Dumps]

By | March 14, 2018

BraindumpsVCE presents a reliable Dell Certified Professional DNDNS-200 certification exam dumps material with 100% success assurity. BraindumpsVCE offers you all DNDNS-200 exam related material in two easy format, PDF and Practice Software. No matter how you like to learn our Dell DNDNS-200 exam Practice Software has the various options for every learning style. We provide you 100% latest DNDNS-200 exam questions. All the Dell Networking Professional Dell DNDNS-200 exam content adapts easily to an individual’s work role and learning preferences at any point in the learning journey towards achieving DNDNS-200 certification exam.

♥ VALID DNDNS-200 Exam Questions 2018 ♥

DNDNS-200 exam questions, DNDNS-200 PDF dumps; DNDNS-200 exam dumps:: https://www.dumpsschool.com/DNDNS-200-exam-dumps.html (60 Q&A) (New Questions Are 100% Available! Also Free Practice Test Software!)

Latest Dell DNDNS-200 Dumps Exam Questions and Answers:

Question: 21

A customer has an existing DR solution using SRDF between Symmetrix at their source and backup sites. TimeFinder Clones are also used at the backup site. A new VNX is installed at the backup site. The customer tries to use Incremental SAN Copy to copy data updates from the TimeFinder Clone to live web server LUNs on the VNX. The customer reports they are not able to configure the SAN Copy session. Why does the customer need to rework this solution?

A. The source for Incremental SAN Copy must be a TimeFinder BCV, and the server I/O needs to be stopped.
B. The source for Incremental SAN Copy must be on the VNX, and the server I/O needs to be stopped.
C. The source for Incremental SAN Copy must be on the source Symmetrix, and TimeFinder Snapshot needs to be used.
D. The source for Incremental SAN Copy must be on the VNX, and the data needs to be pushed.

Answer: B

Question: 22

A customer wants to reduce the performance impact incremental SAN Copy (ISC) has on their source LUN. They plan to use a clone between the current source and destination LUNs, and then use the fractured clone as the new ISC source LUN. The source LUN performs two hundred 4 KB random I/O per second, with a 1:1 read/write ratio. The source LUN is 768 GB in size, and the clone will be fractured for five minutes. How much data will be copied to the destination LUN?

A. 11,250 MB
B. 22,500 MB
C. 1,125 MB
D. 4,800 MB

Answer: A

Question: 23

A storage administrator reports they are unable configure SAN Copy connections between two VNX. The required cabling is in place and zoning is correct, but the SP connections still do not appear in Unisphere Manager. What could have caused this issue?

A. SAN Copy is not installed on both VNX arrays.
B. SAN Copy is only licensed for local copies.
C. The SP ports are already being used by hosts.
D. Both VNX arrays are not in the same domain.

Answer: D

Question: 24

A Pool used for FAST VP has the following configuration:
Flash drives: 1,000 GB, with 1,000 GB free
SAS drives: 5,000 GB, with 2,500 GB free
NL-SAS drives: 20,000 GB, with 11,500 GB free
The tiering policy is set to Auto. An additional 600 GB of new data is written to the Pool.
What is the data distribution after the data is written?

A. Flash drives: 960 GB free SAS drives: 2,400 GB free NL-SAS drives: 11,040 GB free
B. Flash drives: 400 GB free SAS drives: 2,500 GB free NL-SAS drives: 11,500 GB free
C. Flash drives: 900 GB free SAS drives: 2,000 GB free NL-SAS drives: 11,500 GB free
D. Flash drives: 970 GB free SAS drives: 2,350 GB free NL-SAS drives: 11,080GB free

Answer: A

Question: 25

You are planning a CIFS DR solution for two existing EMC VNX. Each VNX has dual Control Stations. Each VNX is also configured for a Recover Point protection solution on other VNX LUNs that are non-file related. What recommendation would you give the customer concerning the CIFS DR solution?

A. Configure IP aliasing on the Control Stations for both source and destination VNX systems before configuring VNX Replicator
B. Configure IP aliasing on the Control Stations for both source and destination VNX systems after configuring VNX Replicator
C. Configure IP aliasing on the source VNX system Control Stations before configuring VNX Replicator, and then configure IP aliasing on the destination VNX system Control Stations after configuring VNX Replicator.
D. Configure IP aliasing on the source VNX system Control Stations before configuring VNX Replicator and use RecoverPoint to provide protection of the source VNX Control Stations to the destination VNX.

Answer: A

Question: 26

A customer recently purchased an EMC VNX to be connected to four ESXi 5.0 hosts via FC. Five of the associated VMs (virtual machines) are running SQL Server 2008 R2. To avoid contention, the customer wants the VM’s database and log drives on separate datastores. Which ESXi 5.0 feature would satisfy this requirement?

A. Network interface card teaming
B. Virtual Machine Anti-Affinity
C. Raw Device Mappings
D. VMDK Affinity

Answer: B